Correction signal 1: C [1 - 8]: Correction type

Parameter

Description

Properties

Type

Selection parameter

[0] No correction
[1] Correction as percentage added to current setting value

The maximum correction value is calculated as a percentage of the current setting value and added to the current channel setting value according to the parameterization and the applied correction signal.

[2] Correction with fixed value added to current setting value

The maximum correction value is defined as fixed values and added to the current channel setting value according to the parameterization and the applied correction signal.

[3] Correction with fixed value added to current load position

This setting depends on Correction signal 1: Correction type for load position (example using correction signal 1):

Correction with fixed value added to the current load position

Correction signal 1: Correction type for load position = "[0] Fixed value"

The maximum correction value is defined with fixed values and added to the current channel load position according to the parameterization and the applied correction signal.

Correction in percent added to the current load position

Correction signal 1: Correction type for load position = "[1] Percentage"

The maximum correction value is calculated as a percentage of the current setting value and added to the current channel load position according to the parameterization and the applied correction signal.

Reference

1092, 1093; 1108, 1109; 1124, 1125; 1140, 1141; 1156, 1157; 1172, 1173; 1188, 1189; 1204, 1205

DOC-729420819