Correction signals

An input is provided to connect a correction signal.

The correction signal is applied via

  • the analog input of the FSC-IO 4DI/1AI module or

  • the HMI via the bus system.

seavis compact offers 1 correction signal and seavis pro offers 2.

Addressing (FSC-IO 4DI/1AI module)

Address the module being used as follows:

  • HOST

    Address = 28 (Correction signal 1)

    Address = 29 (Correction signal 2)

  • NET

    Address the network (NET) in the entire system with address 11!