Number of ignition attempts
Ignition attempts in support mode (WIP)
Count of failed ignition attemps of the ignition flame
Reset after failed ignition attempt
Ignition standby time
Reporting ignition attempts / failed ignition attempts
The FSC reports an ignition attempt / failed ignition attempt for a superordinate control system (e.g. for waste incineration plants) via a safety-related output.
Ignition attempt message
The "ignition attempt" output is switched on for the duration of the second safety time + 1 s.
FSC configuration for digital outputs must include the "ignition attempt" output signal.
Failed ignition attempt message
The "failed ignition attempt" output is switched off for 5 s if a safety shut-off is detected within 1 second following activation of the main flame monitor (at the end of the second safety time).
DOC-719497461